Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Model No.: RTU()
Brand: Amrta or OEM
Type: Chiller
Air Tube Material: Galvanized Sheet
Corrosion Durability: General
Operating Voltage: 380/400 VAC
Noise Level: Low
Mounting: Floor Standing
Lifetime: 15~20 years
Certification: CE
Condition: New
Colour: White
Application Fields: Mechanical Engineering, School, Airport, Shopping Mall, Industrial Buildings
Refrigerant: R410A/R407c/R134A/R22
Compressor: Danfoss/Copeland/Panasonic/Daikin
Cooling Capacity: 12kw-300kw
Electric Parts: Schneider Brand
Refrigerant Valves: Danfoss/Emerson Brand
Controller: Syslab Brand Or Siemens PLC(optional)
Power Supply: 380~415V, 440~460V, 50HZ/60HZ
Unit Type: Cooling Only/Heat Pump/Cooling Only With Electric Heater
Packaging: Plywood Casing or standard package suitable for sea and air transport
Productivity: 6000PCS/Year
Transportation: Ocean,Air
Place of Origin: China
Supply Ability: 500PCS/Month
HS Code: 8418612090
Port: Qingdao,Shandong,China
Payment Type: L/C,T/T,Western Union
Incoterm: FOB,CFR,CIF
Amrta air cooled package units all feature active thermodynamic heat recovery. There are specialised models available for Fresh Air Pre-Treatment, Medium Attendance Applications such as retail, bars, restaurants & supermarkets, High Attendance Applications such as cinemas and conference centres, and Full Fresh Air Applications such as projection rooms, kitchens, laboratories etc. The units all feature: Economizer and free cooling, Energy recovery, Electric heater, Hot water coil, Explosion proof, Gas burner etc.
Gas Burner Rooftop Packaged Unit. The running logic of Air Conditioner with Gas Burner is: The gas heating modular use a safe and reliable atmospheric gas burner made of aluminized steel tube heat exchanger designed to offer maximum heat transfer and 92% efficiency (PCI%). It runs with natural gas in an operating range of 1.3-2.6KPa. The standard gas module offers 2 stages of control which helps in improving space comfort by avoiding large supply air temperature deviations. The air flow rate in the burner is controlled as the gas flow is being reduced maintaining the burner to its highest efficiency level. S: 30kW, M: 50kW, L:100kW
Characteristics
01. Structure. Panels and frame are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents.
Technical Data
Model | RTU45 | RTU50 | RTU60 | RTU75 | RTU90 | RTU105 | ||
Cooling capacity | kW | 44.5 | 50 | 60 | 70 | 90 | 105 | |
Heating capacity | kW | 48.7 | 54.3 | 64 | 75.4 | 96.2 | 113.2 | |
Power supply | 380V / 3Ph / 50HZA | |||||||
Cooling power input | kW | 17 | 19.5 | 22.8 | 26.7 | 32.9 | 39.7 | |
Heating power input | kW | 15.6 | 18 | 21 | 24.8 | 30.4 | 36.7 | |
Start current | A | 168 | 186 | 175 | 199 | 197 | 266 | |
Working current in cooling | A | 31.7 | 35.6 | 39.9 | 48.3 | 61 | 70.6 | |
Working current in heating | A | 29.9 | 33.5 | 37.5 | 45.4 | 57.3 | 66.3 | |
Throttle methods | Thermal expansion valve | |||||||
Circuits | 2 | 2 | 2 | 2 | 3 | 3 | ||
Refrigerant | R410A | |||||||
Compressor | Type | Scroll type 380V / 3Ph / 50HZA | ||||||
Qty | 2 | 2 | 2 | 2 | 3 | 3 | ||
Condenser side | ||||||||
Condenser | Type | Al+copper tube | ||||||
Axial fan | Qty | 1 | 1 | 1 | 1 | 2 | 2 | |
Drive | Direct drive | |||||||
Motor power | kW | 0.25 | 0.37 | 0.37 | 0.55 | 0.75 | 0.75 | |
Air flow | m3 /h | 4600 | 7800 | 7800 | 9000 | 12600 | 12600 | |
Evaporator side | ||||||||
Evaporator | Type | Al+copper tube | ||||||
Centrifugal fan | Qty | 1 | 1 | 1 | 1 | 1 | 1 | |
Motor power | kW | 3 | 3 | 4 | 4 | 5.5 | 5.5 | |
Air flow | m3 /h | 7600 | 8500 | 10900 | 12500 | 16000 | 19500 | |
Drive | Direct drive | Belt drive | ||||||
External static pressure(Pa) | 250 | 250 | 300 | 300 | 300 | 300 | ||
Filter | Aluminum frame filter G3 | |||||||
Noise level dB(A) | 73 | 73 | 73 | 75 | 74 | 75 | ||
Dimension | L | mm | 2268 | 2268 | 2298 | 2298 | 2878 | 2878 |
W | mm | 1440 | 1440 | 1650 | 1650 | 2140 | 2270 | |
H | mm | 1167 | 1167 | 1400 | 1400 | 1964 | 1964 | |
Weight | kg | 750 | 770 | 830 | 860 | 1160 | 1350 |
* Performance values refer to the following conditions:
Cooling: room air temperature 27.0°C DB RH 50%, ambient air temperature 35°C;
Heating: room air temperature 20.0°C DB, ambient air temperature 7°C DB / 6°C WB.
** Noise level measured by adopting average value in the noise lab with background noise of 25 dB(A), at a distance of 1.5m high fan speed.
Installation
Product Categories : Rooftop Packaged Unit > Rooftop Packaged Unit With Gas Burner
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.