Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Model No.: WW130~WW2500
Brand: Amrta or OEM
Type: Water-Cooled
Cooling Method: Water-cooled
Unit Structure: Integral
Selected Voltage: 380V/50HZ
Noise Level: Low
Certification: CE
Condition: New
Mounting: On The Ground
Application Fields: Factory, Supermarket, Hospital And So On
Compressor: Bitzer/Hanbell/Fusheng
Refrigerant Parts: Emerson/Danfoss
Electric Parts: Schneider
Controller: Siemens/Punp
Optional: BMS/T3 High Temperature/Heat Recovery
Refrigerant: R22/R407c/R134A
Cooling: 130-2500kw
Heat Exchanger: Shell And Tube Type
Packaging: Plywood Casing or standard package suitable for sea and air transport
Productivity: 5000/Year
Transportation: Ocean
Place of Origin: China
Supply Ability: 400PCS / Month
HS Code: 8418612090
Port: Qingdao,Shandong,China
Payment Type: L/C,T/T,Western Union
Incoterm: FOB,CFR,CIF
Geothermal Heat Pump adopt advanced structure design and reasonable structure matching, the unit energy efficiency ratio is high, the volume is small. Variable capacity adjustment, flexible start and stop, comfortable and energy saving. Large contact screen, powerful control function, with fault self diagnosis and other functions. Multiple safety protection measures, safe and reliable operation of the unit. Easy install and cover a small area, low noise and vibration. Amrta Water to Water Source Heat Pump Unit are available as heating only, cooling only, heating and cooling or heating and cooling with domestic hot water units, making them ideal for a variety of applications including geothermal and boiler. These units provide high efficiencies with precise metering of refrigerant flow under all expected operating conditions, and offer efficient, standard design features as well as additional value options to suit a building owner's needs.
Application areas
● Offices, Hotels, Hospitals, Apartment, Villa
● Factory, Shopping center, Schools
● Commercial buildings
Why this choice?
● Semi - hermetic screw compressor
● Great environmental and economic benefit
● High efficiency shell and tube evaporator
● Electronic controller with BMS system
● Widely cooling capacity range
Characteristics
01.29 sizes available ranging from 127 kW to 2450 kW heating capacity.
02.Reusable: using solar energy stored in earth as cooling & heating source.
03.Great environmental and economic benefit: no boiler or cooling tower; less space, less CO2 and less initial investment.
04.Acting as multifunction Air Conditioner such as cooling, heating, sanitary hot water separately or simultaneously.
05.Wide application as hotel, apartment, villa, factory, shopping center, office building, school, etc.
06.Semi-hermetic screw compressor for mod.130 to 2500. Each compressor is equipped with a crankcase heater and a thermal overload cut-out; the screw compressor is also complete with a built-in electronic protection with temperature sensor located directly in the motor winding and on the discharge line.
07.The refrigerant circuit is complete with sight glass, filter drier, high and low pressure gauges, solenoid valve, direct expansion valve, high and low pressure switch.
08.Shell and tube dry expansion type condenser, factory insulated with flexible close cell material.
09.Shell and tube type evaporator, factory insulated with flexible close cell material.
10.The electric panel consists of compressor breaker, compressor contactor, phase sequence relay, control circuit breaker, microprocessor control with function display. LCD display, touch screen control panel as standard.
11. Automatic operation dramatically reducing maintenance cost thanks to reliable microprocessor system.
12. For the units with semi-hermetic screw compressor, an infinitely variable capacity control system that is capable of exactly matching the demand requirement of the system is to be supplied. This system is to provide precise and stable control of supply water temperature over the complete range of operating conditions.
13.Optional
Electronic expansion valve.
Desuperheater as optional.
Electronic controller with BMS system.
Low noise compressor cabinet or outside full cover
Channel Steel base
Technical Data
Model Unit 130 170 200 240 260 280 310 360 380 420 Cooling capacity* kW 130 170 200 240 260 280 310 360 380 420 Heating capacity* kW 127 167 196 235 255 274 304 353 372 412 Power supply 380-415V/3Ph/50Hz Compressor Qty/refrigerant circuit Nr. 1/1 1/1 1/1 1/1 1/1 1/1 1/1 1/1 1/1 1/1 Cooling power input* kW 24 31 37 44 48 52 57 67 70 78 Heating power input* kW 43 56 66 80 86 93 103 120 126 140 Energy adjustment steps step 25% - 100% Max. current for wiring A 87 108 128 165 165 165 165 185 185 258 Refrigerant charge kg 23 30 36 43 46 50 55 64 68 75 Evaporator Water side pressure drop kPa 42 45 45 45 45 46 46 46 47 46 Pipe size mm DN65 DN80 DN100 DN100 DN100 DN100 DN100 DN125 DN125 DN125 Water flow rate in cooling* m3/h 22 29 34 41 45 48 53 62 65 72 Water flow rate in heating* m3/h 9 12 14 17 18 19 22 25 26 29 Condenser Water side pressure drop kPa 42 45 44 44 45 45 44 44 44 42 Pipe size mm DN80 DN80 DN100 DN100 DN100 DN100 DN100 DN125 DN125 DN125 Water flow rate in cooling* m3/h 12 16 19 22 24 26 29 33 35 39 Water flow rate in heating* m3/h 22 29 34 40 44 47 52 61 64 71 Dimensions Length mm 2635 2760 2740 2880 2870 2870 2970 3170 3280 3280 Width mm 1090 1115 1175 1125 1125 1125 1230 1200 1285 1285 Height mm 1625 1555 1650 1645 1685 1685 1685 1685 1805 1805 Net weight kg 1600 1800 1900 2000 2100 2200 2250 2400 3000 3100 Noise level** dB(A) 68 69 69 70 70 72 73 73 73 73 Model Unit 480 530 610 680 710 760 860 960 1000 1120 Cooling capacity* kW 480 530 610 680 710 760 860 960 1000 1120 Heating capacity* kW 470 519 598 666 696 745 843 941 980 1098 Power supply 380-415V/3Ph/50Hz Compressor Qty/refrigerant circuit Nr. 1/1 1/1 1/1 1/1 2/2 2/2 2/2 2/2 2/2 2/2 Cooling power input* kW 89 98 113 126 131 141 159 178 185 207 Heating power input* kW 159 176 203 226 236 252 286 319 332 372 Energy adjustment steps step 25% - 100% 12.5% - 100% Max. current for wiring A 302 302 357 378 2×185 2×185 2×258 2×258 2×302 2×302 Refrigerant charge kg 85 94 108 121 126 135 153 171 178 199 Evaporator Water side pressure drop kPa 46 46 46 47 47 46 47 46 46 46 Pipe size mm DN125 DN125 DN125 DN150 DN150 DN150 DN150 DN200 DN200 DN200 Water flow rate in cooling* m3/h 83 91 105 117 122 131 148 165 172 193 Water flow rate in heating* m3/h 33 37 42 47 49 53 60 67 70 78 Condenser Water side pressure drop kPa 42 42 44 42 44 42 44 42 44 44 Pipe size mm DN125 DN125 DN125 DN150 DN125 DN125 DN125 DN125 DN125 DN150 Water flow rate in cooling* m3/h 44 49 57 63 66 70 80 89 93 104 Water flow rate in heating* m3/h 81 89 103 115 120 128 145 162 169 189 Dimensions Length mm 3505 3505 3505 3520 4005 4505 4505 4505 4560 4560 Width mm 1280 1315 1375 1380 1415 1415 1415 1415 1460 1460 Height mm 1970 1990 1980 1980 1975 2000 2000 2000 2090 2090 Net weight kg 3500 3800 4000 4100 4210 4400 4740 5600 6600 6800 Noise level** dB(A) 74 74 74 73 74 74 74 74 74 74
Model Unit 1200 1250 1360 1470 1720 1840 2000 2350 2500 Cooling capacity* kW 1200 1250 1360 1470 1720 1840 2000 2350 2500 Heating capacity* kW 1176 1225 1333 1441 1686 1803 1960 2303 2450 Power supply 380-415V/3Ph/50Hz Compressor Qty/refrigerant circuit Nr. 2/2 2/2 2/2 4/4 4/4 4/4 4/4 4/4 4/4 Cooling power input* kW 222 231 252 272 319 341 370 435 463 Heating power input* kW 399 415 452 488 571 611 664 781 831 Energy adjustment steps step 12.5% - 100% 6.25% - 100% Max. current for wiring A 2×357 2×357 2×378 4×185 4×258 4×258 4×302 4×357 4×357 Refrigerant charge kg 213 222 242 261 306 327 356 418 444 Evaporator Water side pressure drop kPa 46 46 46 45 45 46 46 47 47 Pipe size mm DN200 DN200 DN200 2×DN150 2×DN150 2×DN200 2×DN200 2×DN200 2×DN200 Water flow rate in cooling* m3/h 206 215 234 253 296 316 344 404 430 Water flow rate in heating* m3/h 84 87 95 102 120 128 139 164 174 Condenser Water side pressure drop kPa 44 42 45 52 52 52 52 52 52 Pipe size mm DN150 DN150 DN150 2×DN200 2×DN200 2×DN200 2×DN200 2×DN200 2×DN200 Water flow rate in cooling* m3/h 111 116 126 136 159 170 185 218 232 Water flow rate in heating* m3/h 202 211 229 248 290 310 337 396 421 Dimensions Length mm 4660 4660 4660 4600 4650 4690 4730 4780 4800 Width mm 1585 1585 1585 2250 2270 2300 2340 2380 2400 Height mm 2215 2215 2240 2350 2380 2410 2450 2470 2500 Net weight kg 7000 7400 8000 8800 9000 9800 11600 12300 13000 Noise level** dB(A) 74 74 76 80 80 81 81 82 82
* Performance values refer to the following conditions:
Cooling: condenser water inlet/outlet temperature: 18ºC/29ºC, evaporator water inlet/outlet temperature: 12ºC/7ºC.
Heating: condenser water inlet/outlet temperature: 40ºC/45ºC, evaporator water inlet/outlet temperature: 15ºC/7ºC.
** Noise level measured in free field condition at distance of 1 meter.