Overview
Product Attributes

Model No.RTU12~RTU300

BrandAmrta or OEM

TypeChiller

Air Tube MaterialGalvanized Sheet

Corrosion DurabilityHigher

Operating Voltage380/400 VAC

Noise LevelLow

MountingFloor Standing

Lifetime15~20 years

CertificationCE

ConditionNew

Application FieldsMechanical Engineering, School, Airport, Shopping Mall, Industrial Buildings

RefrigerantR410A/R407c/R134A/R22

Cooling Capacity12kw-300kw

Electric PartsSchneider Brand

Power Supply380~415V, 440~460V, 50HZ/60HZ

Compressor BrandCopeland/Danfoss/Panasonic/Daikin

Refrigerant ValvesEmerson/Danfoss Brand

ControllerSyslab Brand Or Siemens PLC Controller(optional)

Energy RecoveryOptional

Supply Ability & Additional Information

PackagingPlywood Casing or standard package suitable for sea and air transport

Productivity6000PCS/Year

TransportationOcean

Place of OriginChina

Supply Ability500PCS/Month

HS Code8418612090

PortQingdao,Shandong,China

Payment TypeL/C,T/T,Western Union

IncotermFOB,CFR,CIF

Packaging & Delivery
Selling Units:
Set/Sets
Package Type:
Plywood Casing or standard package suitable for sea and air transport

Hot Water Coil Rooftop Packaged Aircon represent years of research and design with one goal in mind – making your family
comfortable. With durable, lasting comfort and the option to choose 
Aircon Rooftop with Hot Water Coil. And Modular Rooftop Air Handling Unit with multi-speed
blowers, these models can provide enhanced summer dehumidification when managed by select thermostats.


Characteristics

01.Structure. Panels and frame are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents.

Direct expansion coils with condensate drain tray.


02. Hermetic compressor. High efficiency scroll compressor for the whole range, with built-in thermal overload cut-out and crankcase heater, mounted on rubber vibration dampers. Ripple type acoustic insulation for compressor section, and thermal insulation for coil and fan section, low noise.


03.Centrifugal fan. Forward curve centrifugal fans for air treatment section and axial fans for condensation section. Front, side and underside air discharge of the treatment unit. High external pressure, long air supply distance.


04. Electric panel. Electric panel consists of breakers and contactors for compressors and fan motors, phase sequence relay and other necessary protection devices for the main components.


05. Easy operation line controller
Cooling/Heating/Auto
Error indication

Timing on/off


06. Optional

Economizer with fresh, return air dampers and fresh air hood

Free cooling function for low ambient temperature

Low ambient control device for operation of outdoor units at ambient temperatures from less than 20°C down to -10°C
BMS devices
T3 (Tropical climate)
Roof curb
Metal/aluminum filter
100% heat recovery
Evaporating section: double skin with 50mm polyurethane foam
Optional water heating coil
Metal or plastic mesh on condenser coil
Optional supply/return air configurations
Upgraded plug fan

G4 filter, plate and bag filter


07. Economizer and Free Cooling. 

It is one of the most important features of this rooftop as it maximise seasonal efficiency by reducing the use of thermodynamic cooling in mid season.

Thermodynamic cooling can be replaced by Free Cooling when outdoor temperature is below the building set point saving up to 15% on annual energy consumption.

Rooftop units are supplied with economizer and fresh air hood to improve comfort through better fresh air management and allow energy savings with free cooling.


08. Exhaust air
Gravity exhaust damper
Gravity exhaust damper Installed with economizer assembly, gravity exhaust damper relief pressure when outside air is being introduced in the system. It is a cheap and smart way to avoid over pressure in a building.
Power exhaust fans
Installed with economizer assembly, it provides exhaust air pressure relief when high levels of fresh air are being introduced in the system.

Interlocked to run when return air dampers are being closed and supply air blower is in operation. The extraction fans run when outdoor air dampers are at least 50% open (adjustable). It is also overload protected. A gravity exhaust damper is supplied with this option to prevent air from entering the unit during shutdown. The power exhaust fans have been size to exhaust 50% of the nominal air flow of the Rooftop Packaged Unit.


Technical Data

Model 

RTU45

RTU50

RTU60

RTU75

RTU90

RTU105

Cooling capacity

kW

44.5

50

60

70

90

105

Heating capacity

kW

48.7

54.3

64

75.4

96.2

113.2

Power supply

  380V / 3Ph / 50HZA

Cooling power input

kW

17

19.5

22.8

26.7

32.9

39.7

Heating power input

kW

15.6

18

21

24.8

30.4

36.7

Start current

A

168

186

175

199

197

266

Working current in cooling

A

31.7

35.6

39.9

48.3

61

70.6

Working current in heating

A

29.9

33.5

37.5

45.4

57.3

66.3

Throttle methods

Thermal expansion valve

Circuits

2

2

2

2

3

3

Refrigerant

R410A

Compressor

Type

Scroll type        380V / 3Ph / 50HZA

Qty

2

2

2

2

3

3

Condenser side

Condenser

Type

Al+copper tube

Axial fan

Qty

1

1

1

1

2

2

Drive

Direct drive

Motor power

kW

0.25

0.37

0.37

0.55

0.75

0.75

Air flow

m/h

4600

7800

7800

9000

12600

12600

Evaporator side

Evaporator

Type

Al+copper tube

Centrifugal fan

Qty

1

1

1

1

1

1

Motor power

kW

3

3

4

4

5.5

5.5

Air flow

m/h

7600

8500

10900

12500

16000

19500

Drive

Direct drive

Belt drive

External static pressure(Pa)

250

250

300

300

300

300

Filter

Aluminum frame filter G3

Noise level dB(A)

73

73

73

75

74

75

Dimension

L

mm

2268

2268

2298

2298

2878

2878

W

mm

1440

1440

1650

1650

2140

2270

H

mm

1167

1167

1400

1400

1964

1964

Weight

kg

750

770

830

860

1160

1350

* Performance values refer to the following conditions:
Cooling: room air temperature 27.0°C DB RH 50%, ambient air temperature 35°C;
Heating: room air temperature 20.0°C DB, ambient air temperature 7°C DB / 6°C WB.
** Noise level measured by adopting average value in the noise lab with background noise of 25 dB(A), at a distance of 1.5m high fan speed.


Product Pictures

Rooftop packaged aircon Unitary Rooftop packaged air conditioning


Overseas Simple Projects

Rooftop Packaged Chiller


Main Spare Parts

Rooftop Packaged Unit



We are MANUFACTURER of Central Air Conditioner. Our units cover Rooftop packaged unit(10kW-240kW), Air Cooled Water Chiller(8kW-1200kW), Geothermal Heat Pump(10kW-2500kW), VRF system and Fan Coil unit etc. All of our products are qualified with CE certificate.


Our Product Ranges

Product Range

Product Categories : Rooftop Packaged Unit > Rooftop Packaged Unit With Hot Water Coil

Download
Email to this supplier
  • *Subject:
  • *To:
    Mr. Richard Lee
  • *Email:
  • *Message:
    Your message must be between 20-8000 characters
Send Inquiry
*
*

Related Products List

Home

Product

Whatsapp

About Us

Inquiry

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send