Communicate with Supplier? Supplier
Richard Lee Mr. Richard Lee
What can I do for you?
Chat Now Contact Supplier
 Tel:0086-531-88901036 Email:info@amrta.com.cn
Home > Products > Fan Coil > Chilled Water Fan Coil > Chilled Water Fan Coil Unit
Chilled Water Fan Coil Unit
Chilled Water Fan Coil Unit
Chilled Water Fan Coil Unit
Chilled Water Fan Coil Unit
Chilled Water Fan Coil Unit
  • Chilled Water Fan Coil Unit
  • Chilled Water Fan Coil Unit
  • Chilled Water Fan Coil Unit
  • Chilled Water Fan Coil Unit
  • Chilled Water Fan Coil Unit

Chilled Water Fan Coil Unit

    Unit Price: USD 65 / Set/Sets
    Payment Type: L/C,T/T,Western Union
    Incoterm: FOB,CFR,CIF
    Min. Order: 1 Set/Sets
    Delivery Time: 30 Days

Download:

Basic Info

Model No.: 34~238WA, 34~238KM

Type: Fan Coil Unit

Corrosion Durability: General

Noise Level: Ordinary

Lifetime: 15~20 years

Certification: CE

Condition: New

Operating Voltage: 220-240V, 50/60Hz

Application Fields: Office, Home, Villa And Resterant Etc

Mounting: Ceiling Mount, Floor Standing

Additional Info

Packaging: Plywood Casing or standard package suitable for sea and air transport

Productivity: 10000PCS/Year

Brand: Amrta or OEM

Transportation: Ocean,Air

Place of Origin: China

Supply Ability: 10000PCS/Month

HS Code: 8415830000

Port: Qingdao,Shandong,China

Product Description

Water Chilled Fan Coil Unit with various series, such as Cassette Fan Coil Unit, Concealed Type Fan Coil Unit, Exposed Type Fan Coil Unit and Wall Mounted Fan Coil Unit. For Exposed Type Fan Coil Unit, it can be with legs or without legs, if with legs, maybe install it on the floor, if without legs, maybe install it on the wall. For the unit, left type or right type, when make the order please inform us. The difference between left type and right type is: please face the supply air vent, the water pipe in the left is the left type, otherwise the unit will be right type.


Product Description
01.Efficient and Energy Saving. Efficient ABS blower which is light weighted while statically and dynamically balanced. Excellent thinwall copper tube and efficient hydrophilic aluminum fin are under water pressure bonded treatment. Patent inverse crossing circuit to reach the best heat transfer efficiency. Brass water distributor is used for improving water flow distribution, in order to provide better heat transfer effect.
02.Quiet Operation.Low noise and permanent capacity motor, unique ABS centrifugal blower, all of them pass dynamically balance test, to ensure unit operate quietly and efficiently. 3-speed motor, ball bearing, long lifespan; rubber vibration isolator reduces operation noise.
03.Stable and Reliable. U-shaped tube bending, reducing soldered dot and leakage point. Drain pan is made of high grade stainless steel plate, modeling processing; surface has been under hot dipped electroforming painting treatment. 7mm PE thermal insulation foam is applied on the drain pan to prevent condensation and leakage from occurring. Furthermore the width and length of the drain pan has been specifically designed to accommodate the water drop from the water inlet / outlet and electrically operated valve.There is fuse in power supply inlet side to prevent motor burned because of wrong wiring. Reliable and stable motor which enjoys good reputation in the market.
04. Different Models Static pressure: 12Pa, 30Pa, 50Pa.
Fan coil unit series: horizontal exposed type, horizontal concealed type, vertical concealed type, vertical exposed type, cassette type, large air volume fan coil unit. Accessories: 3-speed switch, return air box, extended drain pan, electronic two-way valve, electrical heater, air cleansing module. All above are for your selection.


Concealed Type Fan Coil Unit

Performance Parameter

Model

34WA

51WA

68WA

85WA

102WA

136WA

170WA

204WA

238WA


Rated air volume m³/h

H

340

510

680

850

1020

1360

1700

2040

2380

M

255

383

510

638

765

1020

1275

1530

1785

L

170

255

340

425

510

680

850

1020

1190


Rated cooling capacity

W

H

1800

2700

3600

4500

5400

7200

9000

10800

12600

M

1440

2160

2880

3600

4320

5760

7200

8640

10080

L

1170

1755

2340

2925

3510

4680

5850

7020

8190


Rated heating capacity

W

H

2700

4050

5400

6750

8100

10800

13500

16200

18900

M

2160

3240

4320

5400

6480

8640

10800

12960

15120

L

1755

2633

3510

4388

5265

7020

8775

10530

12285


Input power

W

12Pa

H

37

52

62

76

86

134

152

189

228

30Pa

H

44

59

72

87

100

156

174

212

253

50Pa

H

49

66

84

100

108

174

210

250

300


Noise

dB(A)

12Pa

H

37

39

41

43

45

46

48

50

52

30Pa

H

40

42

44

46

47

48

50

52

54

50Pa

H

42

44

46

47

49

50

52

54

56

Water volume kg/h

390

550

700

820

910

1340

1590

1800

2070

Water pressure loss kPa

≤30

≤30

≤30

≤30

≤40

≤40

≤40

≤40

≤50


Weight kg

Without plenum box

12.5

14

14

15.5

16.5

22.5

30

33

33.5

With plenum box

14.5

16

17

19.5

20.5

27.5

35

38

39.5


Motor

Type

E class insulation, permanent capacitor, 3 speed fan

Qty

1

1

1

1

1

2

2

2

3


Fan

Type

Double inlet, forward curve, multi blades, centrifugal fan

Type

1

2

2

2

2

3

4

4

4

Water connection pipe

3/4" (DN20)

Condensed water pipe

3/4" (DN20)

Max working pressure

1.6MPa

Power supply

AC 220V/50Hz

Note:

1. Cooling capacity is based on air inlet temperature 27oC DB/19.5oC WB, entering water temperature 7oC, T5oC.
2. Heating capacity is based on air inlet temperature 21oC, entering water temperature 60oC, air flow volume and water flow rate are the same with cooling mode.
3. MPT-Mole pipe thread, FPT-Female pipe thread.
4. ESP for C and F series is 0Pa.
5. For FVE, FVC series, there is no Model 140; the performance parameters of FVE and FVC are the same with FHC.
6. Specifications in this catalog are subject to change without notice.


Model

34KM

51KM

68KM

85KM

102KM

136KM

170KM

204KM

238KM

Air flow [m3/h]

H

340

510

680

850

1020

1360

1700

2040

2380

M

280

390

520

640

790

1030

1290

1500

1800

L

180

260

350

430

520

690

860

1030

1200

Total cooling capacity *

[W]

H

2000

3000

3700

5000

5600

7300

9900

11000

12800

Heating capacity * [W]

H

3000

4800

5500

7200

8200

10800

14500

16800

19200

Fan motor

Nominal power input

W

37

52

62

76

96

132

152

189

220

Nominal current input

A

0.162

0.23

0.276

0.338

0.417

0.588

0.663

0.824

0.976

Water flow rate

m3/h

0.42

0.522

0.62

0.86

0.98

1.22

1.58

1.92

2.2

Water pressure drop

kPa

14

14

16

18

22

25

39

44

44

Water connections

inch

ZG 3/4``

Drain pipe

mm

26

Sound pressure level **

[dB(A)]

H

37

39

41

43

45

46

47

50

52

M

34

36

38

39

42

43

44

46

48

L

30

32

35

36

38

39

40

42

44

Net Dimension W/D/H

mm

Unit

580*580*290

710*710*290

832*832*290

Panel

680*680*30

830*830*30

980*980*30

Power supply

/

220V/1Ph/50Hz

Net weight

kg

Unit

25

25

26

28

29

29

36

38

38

Panel

2.5

4

5

Note:* The data are referred to the following conditions:
Cooling: room temperature: 27 ºC, DB / 19.5 ºC WB; water temperature: 7/12 ºC, high speed.
Heating: room temperature: 21 ºC, water inlet temperature: 70 ºC, high speed. Water flow rate same as in cooling operation.
** Sound pressure measured in anechoic room 1.5 m away from the unit.

Chilled Water Fan Coil Unit

Exposed Type Fan Coil UnitConcealed Type Fan Coil Air Conditioner

Looking for ideal Chilled Water Cassette Fan Coil Manufacturer & supplier ? We have a wide selection at great prices to help you get creative. All the Chilled Water Concealed Fan Coil are quality guaranteed. We are China Origin Factory of Chilled Water Exposed Fan Coil. If you have any question, please feel free to contact us.

Product Categories : Fan Coil > Chilled Water Fan Coil

Email to this supplier
  • Mr. Richard Lee
  • Your message must be between 20-8000 characters

Related Productslist

Home

Phone

Skype

Inquiry