Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Model No.: WW()
Brand: Amrta or OEM
Applicable Industry: Hotels, Garment Shops, Building Material Shops, Machinery Repair Shops, Manufacturing Plant, Food &Amp; Beverage Factory, Farms, Restaurant, Home Use, Retail, Food Shop, Printing Shops, Construction Works, Energy &Amp; Mining, Food &Amp; Beverage Shops, Advertising Company
Status: New
Species: Cabinet Air Conditioner, Chiller
Place Of Origin: China
Operating Voltage: 380/400 Vac
Installation Method: Floor Standing
Certification: Ce
Warranty Period: 1 Year
Core Selling Point: Sustainable, Automatic, High-Accuracy, Competitive Price, Low Maintenance Cost, Easy To Operate, High Safety Level, High Productivity, Famous Brand Low Voltage Components, Remote Monitoring, Long Service Life, Remote Control, Patented Product, Energy Saving, Low Noise Level, Famous Brand Motor, Famous Brand Plc, Voice Navigation, Accurate Temperature Control
Core Component Warranty Period: 1 Year
Noise Level: Ultra Low
Mounting: Floor Standing
Lifetime: 15~20 years
Certification: CE
Condition: New
Type: Water To Water
Power Supply: 220/1/50, 380/3/50
Cooling Capacity: 10kW~133kW
Compressor: Hermetic Scroll Compressor
Evaporator: Plate Type Heat Exchanger
Condenser: Plate Type Heat Exchanger
Refrigerant: R410A/R407C
Application Fields: Office, Hotel, Hospital, School, Industry, Commercial Buildings
Packaging: Wooden Case or Complex Gibre Board
Productivity: 6000PCS/Year
Transportation: Ocean,Air
Place of Origin: China
Supply Ability: 600PCS/Month
Port: Qingdao,Shandong,China
Payment Type: L/C,T/T,Western Union
Incoterm: FOB,CFR,CIF,EXW
Water to Water Heat Pump System with heating and cooling: Close loop or open loop geothermal heating and cooling system with heat recovery for hot sanitary water; the terminal is floor heating or Fan Coil heating and cooling. Ground / Water Source Heat Pump System can adopt water of lake, river, and underground and ground heat source; With compressor and electrical power, it can transmit heat from water into the room in winter, and from room into water in summer to achieve the purpose of Commercial Air Conditioner. Heat from the ground is absorbed at low temperatures into a fluid inside a loop of pipe (a ground loop) buried underground. The fluid then passes through a compressor that raises it to a higher temperature, which can then heat water for the heating and hot water circuits of the house. The cooled ground loop fluid passes back into the ground where it absorbs further energy from the ground in a continuous process as long as heating is required.
Application areas
● Offices, Hotels, Hospitals, Schools
● Industry
● Administration
● Commercial buildings
Why this choice?
High efficiency PHE
Very low noise operation
Single / three phase scroll compressors
Advanced control
Reduced total cost of ownership
Characteristics
Structure
Panels and frame are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents.
Hermetic compressor
Single phase (mod. 10, 12,15) and 3-phase (mod.17 to 130) scroll type compressors, with built-in thermal overload cut-out and crankcase heater, mounted on rubber vibration dampers.
Evaporator
High efficiency plate type heat exchanger, factory insulated with flexible close cell material.
Condenser
High efficiency plate type heat exchanger, factory insulated with flexible close cell material.
Desuperheater
High efficiency stainless steel brazed plate heat exchanger, factory insulated with flexible close cell material.
Refrigerant circuit
Copper tube connection with charge valves, filter drier, thermostatic expansion valve (capillary for mod.10 to 15), gas-liquid separator, high pressure switch and low pressure switch.
The heat pump units are complete also with 4-way valve and one way valve.
Hydraulic circuit
Built with user side and source side water inlet/outlet connectors, water discharge connectors, air vent valve (mod.10 to 30 the user side is complete also with expansion vessel, water pump and flow switch).
Electric panel
• Compressor contactor
• Compressor protection breaker
• User side water pump contactor (for mod.10 to 30)
• User side water pump breaker (for mod.10 to 30)
• Microprocessor with function display
Optional
• Sight glass which must be installed in factory
• Source side flow switch
• Source side water pump
• Anti-vibration rubber
• Metallic filter for the water circuit
• Heat recovery exchanger
• Tube in tube heat exchanger
Water Source Heat Pump Unit Technical Data
Model | Unit | 10 | 12 | 15 | 20 | 25 | 30 | 40 | 45 | 50 |
Nominal cooling capacity* | kW | 10 | 12 | 15 | 20 | 25 | 30 | 40 | 45 | 50 |
Nominal heating capacity** | kW | 11.6 | 14 | 17.5 | 21 | 27.3 | 34.6 | 41.7 | 47 | 55.9 |
Power suplly | V/PH/Hz | 220/1/50 | 380/3/50 | |||||||
Hermetic compressors | ||||||||||
Qty | Nr. | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 | 2 |
Cooling power input* | kW | 2.77 | 3.22 | 3.89 | 4.21 | 5.63 | 7.09 | 8.24 | 10.4 | 11.04 |
Cooling current* | A | 13.8 | 16.2 | 19.1 | 7.8 | 10.6 | 12.8 | 14.9 | 18.8 | 20.1 |
Heating power input** | kW | 3.51 | 4.15 | 5.05 | 5.76 | 7.63 | 9.69 | 11.34 | 13.97 | 14.77 |
Heating current* | A | 17.1 | 20.3 | 24.5 | 10.2 | 13.6 | 16.8 | 19.7 | 24.3 | 25.8 |
User side heat exchanger | ||||||||||
Pressure drop | kPa | 33 | 33 | 36 | 38 | 38 | 38 | 40 | 40 | 42 |
Water flow | m³/h | 1.7 | 21 | 2.6 | 3.4 | 4.3 | 5.2 | 6.9 | 8.1 | 8.6 |
Water pipe | DN | 25 | 25 | 25 | 25 | 40 | 40 | 40 | 40 | 40 |
Source side heat exchanger | ||||||||||
Pressure drop | kPa | 33 | 33 | 36 | 38 | 38 | 38 | 40 | 40 | 42 |
Water flow | m³/h | 0.7 | 0.8 | 1 | 1.2 | 1.6 | 2 | 2.5 | 2.5 | 3.3 |
Water pipe | DN | 25 | 25 | 25 | 25 | 40 | 40 | 40 | 40 | 40 |
Water pump | ||||||||||
power input | kW | 0.4 | 0.49 | 0.49 | 0.55 | 0.75 | 0.75 | 0.92 | 1.05 | 1.05 |
current | A | 2.2 | 2.4 | 2.4 | 1.1 | 1.2 | 1.2 | 1.5 | 2 | 2 |
Water head | m | 17 | 20 | 18 | 16 | 19 | 16 | 17 | 18 | 17 |
Dimension( mm) | L | 820 | 820 | 820 | 820 | 1400 | 1400 | 1400 | 1400 | 1400 |
W | 575 | 575 | 575 | 575 | 850 | 850 | 850 | 850 | 850 | |
H | 910 | 910 | 910 | 910 | 1050 | 1050 | 1050 | 1050 | 1050 | |
Sound pressure level*** | dB(A) | 56 | 58 | 62 | 62 | 62 | 64 | 64 | 66 | 66 |
Net weight | kg | 130 | 140 | 150 | 180 | 265 | 280 | 320 | 340 | 360 |
Model | Unit | 55 | 60 | 68 | 75 | 95 | 110 | 130 | 150 |
Nominal cooling capacity* | kW | 56 | 62 | 69 | 75 | 94 | 113 | 130 | 150 |
Nominal heating capacity** | kW | 62.2 | 70.1 | 76.4 | 83.4 | 105.1 | 124.1 | 140.1 | 165.4 |
Power suplly | V/PH/Hz | 380/3/50 | |||||||
Hermetic compressors | |||||||||
Qty | Nr. | 2 | 2 | 2 | 4 | 3 | 3 | 4 | 4 |
Cooling power input* | kW | 11.03 | 12.66 | 13.7 | 14.64 | 18.99 | 22.11 | 25.32 | 29.48 |
Cooling current* | A | 19.6 | 22.8 | 24.3 | 26.8 | 34.2 | 38.7 | 45.6 | 51.6 |
Heating power input** | kW | 15.41 | 17.02 | 18.71 | 20.84 | 25.53 | 30.6 | 34.04 | 40.8 |
Heating current* | A | 26.3 | 29.4 | 31.9 | 36.4 | 44.1 | 51.6 | 58.8 | 68.8 |
User side heat exchanger | |||||||||
Pressure drop | kPa | 42 | 48 | 48 | 50 | 52 | 52 | 55 | 55 |
Water flow | m³/h | 9.6 | 10.7 | 11.9 | 12.9 | 16.2 | 19.4 | 22.4 | 25.8 |
Water pipe | DN | 50 | 50 | 50 | 50 | 65 | 65 | 80 | 80 |
Source side heat exchanger | |||||||||
Pressure drop | kPa | 42 | 48 | 48 | 50 | 52 | 52 | 55 | 55 |
Water flow | m³/h | 3.7 | 4.1 | 4.5 | 4.9 | 6.2 | 7.3 | 8.3 | 9.7 |
Water pipe | DN | 50 | 50 | 50 | 50 | 65 | 65 | 80 | 80 |
Water pump | |||||||||
Power input | kW | / | / | / | / | / | / | / | / |
Current | A | / | / | / | / | / | / | / | / |
Water head | m | / | / | / | / | / | / | / | / |
Dimension( mm) | L | 1400 | 1400 | 1400 | 1400 | 1400 | 1850 | 1850 | 1850 |
W | 850 | 850 | 850 | 850 | 850 | 880 | 880 | 880 | |
H | 1050 | 1050 | 1050 | 1050 | 1050 | 1250 | 1250 | 1250 | |
Sound pressure level*** | dB(A) | 68 | 72 | 72 | 72 | 73 | 73 | 74 | 74 |
Net weight | kg | 280 | 300 | 340 | 360 | 460 | 500 | 550 | 620 |
Performance values refer to the following conditions:
* Source side water inlet/outlet temperature 18ºC/29ºC, user side water inlet/outlet temperature 12ºC/7ºC.
** Source side water inlet/outlet temperature 15ºC/7ºC, user side water inlet/outlet temperature 40ºC/45ºC.
*** Sound pressure measured at a distance of 1 m and a height of 1.5 m above the ground in an open field.
Product Categories : Heat Pump System > Water Source Heat Pump
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.