Communicate with Supplier? Supplier
Richard Lee Mr. Richard Lee
What can I do for you?
Chat Now Contact Supplier
 Tel:0086-531-88901036 Email:info@amrta.com.cn
Home > Products > Heat Pump System > Water To Air Heat Pump > Water to Air Heat Pump Packaged Air Conditioner
Water to Air Heat Pump Packaged Air Conditioner
Water to Air Heat Pump Packaged Air Conditioner
Water to Air Heat Pump Packaged Air Conditioner
  • Water to Air Heat Pump Packaged Air Conditioner
  • Water to Air Heat Pump Packaged Air Conditioner
  • Water to Air Heat Pump Packaged Air Conditioner

Water to Air Heat Pump Packaged Air Conditioner

    Unit Price: USD 800 / Set/Sets
    Payment Type: L/C,T/T,Western Union
    Incoterm: FOB,CFR,CIF
    Min. Order: 1 Set/Sets
    Delivery Time: 30 Days

Download:

Basic Info

Model No.: WCP()

Type: Central Air Conditioners

Indoor Machine Noise: <23dB

Certification: CE

China Energy Efficiency Standard: Level 1

Cooling/Heating: Cooling/Heating

Power Source: Electrical

Condition: New

Application Fields: Mechanical Engineering, School, Airport, Shopping Mall, Industrial Buildings

Refrigerant: R410A/R407c/R134A/R22

Electric Parts: Schneider Brand

Refrigerant Valves: Danfoss/Emerson Brand

Colour: White

Unit Type: Cooling Only/Heat Pump/Cooling Only With Electric Heater

Compressor Brand: Danfoss/Copeland/Panasonic/Daikin

Cooling Capacity: 2.5kW To 45kW

Controller: Saturn Brand Or Siemens PLC(optional)

Power Supply: 220V-1PH-50HZ/60HZ, 230V-1PH-60HZ

Additional Info

Packaging: Plywood Casing or standard package suitable for sea and air transport

Productivity: 6000PCS/Year

Brand: Amrta or OEM

Transportation: Ocean,Air

Place of Origin: China

Supply Ability: 500PCS/Month

HS Code: 8418612090

Port: Qingdao,Shandong,China

Product Description

Amrta Water to Air Heat Pump Unit designed to provide year round comfort to room occupiers. The water to air packaged Air Conditioner is ideal for multi - unit installations such as high rise offices or hotel buildings, where the flexibility of individual zone control is required. Compact and reliable, these Heat Pump System units can be installed above ceilings, or in other concealed spaces, saving valuable floor space and providing conditioned air direct to required locations. Water cooled packaged units are designed to be used with simple duct layouts. To take maximum advantage of this feature, units should be located as close to the space to be air conditioned as acoustic criteria allows. Multiple small units, utilizing minimal duct lengths, prove more economical than a single large central ducted Air Conditioning unit.


Why this choice?
● Saving space
● Galvanised steel construction
● AMWCP are well insulated to minimise condensation and attenuate noise.

Application areas
● Offices, Hotels, Hospitals
● Administration
● Industry
●Commercial buildings

Water to Air Heat Pump Packaged Unit


Characteristics

01. Structure. Galvanised steel construction, closed cell foam lined compressor and fan compartments, with an insulted and powder coated drain tray for complete moisture protection, the drain tray is easily removed for inspection and cleaning.

02. Refrigerant. Each unit is factory charged with refrigerant R410a, which is deemed to have zero ozone depletion potential.

03. Hermetic compressor. Single phas rotary compressor is used for this type unit, with built-in thermal overload cut-out, mounted on rubber vibratrion damperss.

04. Centrifugal Fan. High efficiency, double inlet centrifugal fan protection level IP44. Low noise, low speed, big air flow and high ESP.
05. Water side heat exchanger. high efficiency coaxial heat exchanger, factory insulated with flexible close cell material.
06. Air Filter. An optional filter integrated return air spigot is available on all models.The filter is a washable polypropylene netmedia. Care should be taken, when locating each unit, that to enough space is provided to enable the one-piece filter to be withdrawn to its full length from either side of the unit.
07. Insulation. AMTKWP are well insulated to minimise condensation and attenuate noise.

08. Electric Heater(Optional). Electric heater is optional on cooling only versions. Electric elements have spirally wound stainless steel fins to give increased area and low surface temperature. They are totally enclosed within the unit and are supplied with safety cutouts. An optional fan run-on timer for rapid heat dissipation is available.
09. Electric Panel
Consists of:
Compressor contactor
Compressor protection breaker
Microprocessor with function display
10. All Models are Equipped with Wire Controller with the Following Features
7 days programmable timer
Auto random restart
Error self diagnostic
11. Safety Protection
High pressure switch
Low pressure switch
Discharge temperature protection
Anti freezing protection


Specification

Model / WCP3.5 WCP5 WCP7 WCP9 WCP12 WCP14
Power supply V/Ph/ Hz 220- 240v/1/50




Cooling
Capacity KW 3.6 5.0 7.25 9.3 12.3 14.8
Sensible cooling capacity KW 2.9 3.7 5.61 7.2 9.48 11.8
Power Input KW 1.02 1.24 2.0 2.58 3.02 4.05
Rated current A 4.40 5.83 9.25 11.5 13.3 18.0
AEER W/W 3.6 3.73 3.65 3.8 4.29 3.86


Heating
Capacity KW 3.82 5.7 7.89 10.2 12.7 15.5
Input KW 1.07 1.4 2.20 2.65 3.28 4.34
Rated current A 4.8 6.35 9.81 11.9 14.43 19.2
ACOP W/W 3.57 4.01 3.60 3.83 3.86 3.59
Max. input consumption KW 1.4 2.4 2.66 4.0 4.2 5.7
Max. current A 6.0 10.0 11.38 17.1 18.0 19.2
Starting current A 20 28 30 40 35 42
External static pressure at (Hi) Pa 60 60 100 120 120 150
Indoor air flow (Hi) l/sec 194 278 378 472 639 750
Indoor noise level(Hi) dB(A) 42 44 45 47 50 52


Dimension
W mm 1250 1250 1250 1360 1685 1820
H mm 445 445 445 495 445 445
D mm 751 800 800 800 800 850
Net Weight kg 75 86 100 103 115 160
water in the water side exchanger kg 0.80 0.86 1.50 1.87 2.20 2.66

Compressor
Type / Rotary Rotary Rotary Rotary Rotary Rotary
Quantity / 1 1 1 1 2 2
Water flow l/sec 0.22 0.29 0.44 0.58 0.73 0.89
Diameter of water in/out pipe DN20 DN20 DN20 DN25 DN25 DN25
Diameter of drain pipe inch 1 1 1 1 1 1
Refrigerant control TXV TXV TXV TXV TXV TXV
Condsate lift pump(option) Flow rate ml/min 2500 2500 2500 2500 2500 2500
Lift height m 4.5 4.5 4.5 4.5 4.5 4.5
Water coil pressure drop kpa 25 40 41 40 51 91

Refrigerant
Type / R410a R410a R410a R410a R410a R410a
Charge g 750 950 1150 1500 1000*2 1150*2

Drain tray
Material / Stainless steel
Insulation Material / 5mm PE

01. Norminal cooling capacity test condition: Water side water inlet/outlet 30ºC/35ºC, Ambient temperature DB 27 ºC, WB 19 ºC.
02. Norminal heating capacity test condition: Water side water inlet 20ºC, Ambient temperature DB 20 ºC, WB 15 ºC.
03. Noise level measured in the noise lab with background noise of 25 dB(A), at a distance of 1 m.
04. As our continuous products improvement, Amrta reserves the right to change specifications and design without notice.

Heat Pump Commercial Chiller


Why Choose Amrta?

Amrta Central Air Conditioning


Product Catalog

Amrta Central Air Conditioner Cooling and Heating

Project

Amrta Central Air Conditioner Application

Looking for ideal Water Cooled Air Conditioner Manufacturer & supplier ? We have a wide selection at great prices to help you get creative. All the Water to Air Packaged Heat Pump are quality guaranteed. We are China Origin Factory of Water Cooled Air Conditioning. If you have any question, please feel free to contact us.

Product Categories : Heat Pump System > Water To Air Heat Pump

Email to this supplier
  • Mr. Richard Lee
  • Your message must be between 20-8000 characters

Related Products List

Home

Phone

Skype

Inquiry