Home > Products > Heat Pump System > Water Source Heat Pump > Water Source Heat Pumps Air Conditioner

Water Source Heat Pumps Air Conditioner

  • $200
    ≥1
    Set/Sets
Payment Type:
L/C,T/T,Western Union
Incoterm:
FOB,CFR,CIF,EXW
Min. Order:
1 Set/Sets
Transportation:
Ocean,Air
Port:
Qingdao,Shandong,China
Share:
  • Product Description
Overview
Product Attributes

Model No.WW()

BrandAmrta or OEM

Applicable IndustryHotels, Garment Shops, Building Material Shops, Machinery Repair Shops, Manufacturing Plant, Food &Amp; Beverage Factory, Farms, Restaurant, Home Use, Retail, Food Shop, Printing Shops, Construction Works, Energy &Amp; Mining, Food &Amp; Beverage Shops, Advertising Company

StatusNew

SpeciesCabinet Air Conditioner, Chiller

Place Of OriginChina

Operating Voltage380/400 Vac

Installation MethodFloor Standing

CertificationCe

Warranty Period1 Year

Core Component Warranty Period1 Year

Noise LevelUltra Low

MountingFloor Standing

Lifetime15~20 years

CertificationCE

ConditionNew

TypeWater To Water

Power Supply220/1/50, 380/3/50

Cooling Capacity10kW~133kW

CompressorHermetic Scroll Compressor

EvaporatorPlate Type Heat Exchanger

CondenserPlate Type Heat Exchanger

RefrigerantR410A/R407C

Application FieldsOffice, Hotel, Hospital, School, Industry, Commercial Buildings

Supply Ability & Additional Information

PackagingWooden Case or Complex Gibre Board

Productivity6000PCS/Year

TransportationOcean,Air

Place of OriginChina

Supply Ability600PCS/Month

PortQingdao,Shandong,China

Payment TypeL/C,T/T,Western Union

IncotermFOB,CFR,CIF,EXW

Packaging & Delivery
Selling Units:
Set/Sets
Package Type:
Wooden Case or Complex Gibre Board

Amrta Multifunction Water Source Heat Pump transfer the heat energy from river, lake or underground water into domestic water for daily use. They can be applied to ultra cold regions and work more efficiently than air to Water Heat Pump System, making the usage of the heat pump unit independent of environment temperature. With water tank, indoor Fan Coil and floor heating system installed to the heat pump, you can have 5 running modes: Single cooling; Single heating; Single hot water supplying; Cooling and hot water supplying; Heating and hot water supplying.


amrta water source heat pump unitwater source heat pump






Application areas

● Offices, Hotels, Hospitals, Schools
● Industry
● Administration
● Commercial buildings


Why this choice?
High efficiency PHE
Very low noise operation
Single / three phase scroll compressors
Advanced control
Reduced total cost of ownership

Characteristics
Structure
Panels and frame are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents.
Hermetic compressor
Single phase (mod. 10, 12,15) and 3-phase (mod.17  to 130) scroll type compressors, with built-in thermal overload cut-out and crankcase heater, mounted on rubber vibration dampers.
Evaporator
High efficiency plate type heat exchanger, factory insulated with flexible close cell material.
Condenser
High efficiency plate type heat exchanger, factory insulated with flexible close cell material.
Desuperheater
High efficiency stainless steel brazed plate heat exchanger, factory insulated with flexible close cell material.
Refrigerant circuit 
Copper tube connection with charge valves, filter drier, thermostatic expansion valve (capillary for mod.10 to 15), gas-liquid separator, high pressure switch and low pressure switch.
The heat pump units are complete also with 4-way valve and one way valve.
Hydraulic circuit
Built with user side and source side water inlet/outlet connectors, water discharge connectors, air vent valve (mod.10 to 30 the user side is complete also with expansion vessel, water pump and flow switch).
Electric panel 
• Compressor contactor
• Compressor protection breaker
• User side water pump contactor (for mod.10 to 30)
• User side water pump breaker (for mod.10 to 30)
• Microprocessor with function display
Optional
• Sight glass which must be installed in factory
• Source side flow switch
• Source side water pump
• Anti-vibration rubber
• Metallic filter for the water circuit
Heat recovery exchanger
• Tube in tube heat exchanger

Water to Water Heat Pump Diagram


Technical Data

Model

Unit

10

12

15

20

25

30

40

45

50

Nominal cooling capacity*

kW

10

12

15

20

25

30

40

45

50

Nominal heating capacity**

kW

11.6

14

17.5

21

27.3

34.6

41.7

47

55.9

Power suplly

V/PH/Hz

220/1/50

380/3/50

Hermetic compressors

Qty

Nr.

1

1

1

1

2

2

2

2

2

Cooling power input*

kW

2.77

3.22

3.89

4.21

5.63

7.09

8.24

10.4

11.04

Cooling current*

A

13.8

16.2

19.1

7.8

10.6

12.8

14.9

18.8

20.1

Heating power input**

kW

3.51

4.15

5.05

5.76

7.63

9.69

11.34

13.97

14.77

Heating current*

A

17.1

20.3

24.5

10.2

13.6

16.8

19.7

24.3

25.8

User side heat exchanger

Pressure drop

kPa

33

33

36

38

38

38

40

40

42

Water flow

m³/h

1.7

21

2.6

3.4

4.3

5.2

6.9

8.1

8.6

Water pipe

DN

25

25

25

25

40

40

40

40

40

Source side heat exchanger

Pressure drop

kPa

33

33

36

38

38

38

40

40

42

Water flow

m³/h

0.7

0.8

1

1.2

1.6

2

2.5

2.5

3.3

Water pipe

DN

25

25

25

25

40

40

40

40

40

Water pump

 power input

kW

0.4

0.49

0.49

0.55

0.75

0.75

0.92

1.05

1.05

 current

A

2.2

2.4

2.4

1.1

1.2

1.2

1.5

2

2

Water head

m

17

20

18

16

19

16

17

18

17

Dimension( mm)

L

820

820

820

820

1400

1400

1400

1400

1400

W

575

575

575

575

850

850

850

850

850

H

910

910

910

910

1050

1050

1050

1050

1050

Sound pressure level***

dB(A)

56

58

62

62

62

64

64

66

66

Net weight

kg

130

140

150

180

265

280

320

340

360

Model

Unit

55

60

68

75

95

110

130

150

Nominal cooling capacity*

kW

56

62

69

75

94

113

130

150

Nominal heating capacity**

kW

62.2

70.1

76.4

83.4

105.1

124.1

140.1

165.4

Power suplly

V/PH/Hz

380/3/50

Hermetic compressors

Qty

Nr.

2

2

2

4

3

3

4

4

Cooling power input*

kW

11.03

12.66

13.7

14.64

18.99

22.11

25.32

29.48

Cooling current*

A

19.6

22.8

24.3

26.8

34.2

38.7

45.6

51.6

Heating power input**

kW

15.41

17.02

18.71

20.84

25.53

30.6

34.04

40.8

Heating current*

A

26.3

29.4

31.9

36.4

44.1

51.6

58.8

68.8

User side heat exchanger

Pressure drop

kPa

42

48

48

50

52

52

55

55

Water flow

m³/h

9.6

10.7

11.9

12.9

16.2

19.4

22.4

25.8

Water pipe

DN

50

50

50

50

65

65

80

80

Source side heat exchanger

Pressure drop

kPa

42

48

48

50

52

52

55

55

Water flow

m³/h

3.7

4.1

4.5

4.9

6.2

7.3

8.3

9.7

Water pipe

DN

50

50

50

50

65

65

80

80

Water pump

 Power input

kW

/

/

/

/

/

/

/

/

 Current

A

/

/

/

/

/

/

/

/

Water head

m

/

/

/

/

/

/

/

/

Dimension( mm)

L

1400

1400

1400

1400

1400

1850

1850

1850

W

850

850

850

850

850

880

880

880

H

1050

1050

1050

1050

1050

1250

1250

1250

Sound pressure level***

dB(A)

68

72

72

72

73

73

74

74

Net weight

kg

280

300

340

360

460

500

550

620

Performance values refer to the following conditions:

* Source side water inlet/outlet temperature 18ºC/29ºC, user side water inlet/outlet temperature 12ºC/7ºC.

** Source side water inlet/outlet temperature 15ºC/7ºC, user side water inlet/outlet temperature 40ºC/45ºC.

*** Sound pressure measured at a distance of 1 m and a height of 1.5 m above the ground in an open field.


Packaged water source heat pumpwater source heat pump unit

Product Categories : Heat Pump System > Water Source Heat Pump

Download
Home > Products > Heat Pump System > Water Source Heat Pump > Water Source Heat Pumps Air Conditioner
Email to this supplier
  • *Subject:
  • *To:
    Mr. Richard Lee
  • *Email:
  • *Message:
    Your message must be between 20-8000 characters
Send Inquiry
*
*

Related Products List

Home

Product

Whatsapp

About Us

Inquiry

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send